      Harmonic Correction Unit

      Eaton’s active harmonic filters, known as Harmonic Correction Units  provide dynamic harmonic mitigation and power factor correction by actively injecting reactive currents into an electrical distribution system to cancel damaging harmonic currents and supporting power factor requirements at the point of connection. 

      Send an email to: nacho@apowersystems.com, or call to +1 813-805-9506
      Product categories
      • Backup Power (UPS)
        • Data Center & Facility UPS
        • Eaton 3S UPS
        • Eaton 5P RM UPS
        • Eaton 5P Tower UPS
        • Eaton 5PX UPS
        • Eaton 5S UPS
        • Eaton 5SC Tower UPS
        • Eaton 9130 Rackmount UPS
        • Eaton 9130 UPS
        • Eaton 9155 UPS
        • Eaton 9170+ UPS
        • Eaton 9355 UPS
        • Eaton 93E UPS
        • Eaton 93PM UPS
        • Eaton 9PX Split Phase 6kVA & 10kVA UPS
        • Eaton 9PX UPS
        • Eaton BladeUPS
        • Eaton Ferrups UPS
        • Network, Server & Storage UPS
      • Infrared Cameras
      • LED Lighting
      • Power Factor Correction Capacitors
      • Power Quality Recorder
      • Sonic Discharge Detector
      • Surge Protective Devices
        • Bussmann by Eaton
        • Eaton PSPD Series
        • Innovative Technology
          • Critical Load
          • Equalizer
          • Marine Grade SPD
          • OEM
          • Protector
          • Residential
          • XT Series
      • Description

      Harmonic correction unit specifications

      HCUn series

      Power electronics3-level IGBT
      Control topologyDigital harmonic FFT
      Digital instantaneous reactive power
      Efficiency and losses208 Vac ≥ 95% Three-phase compensation: ≤ 17.7 W/A
      Three-phase + N compensation: ≤ 19.7 W/A 380–415 Vac ≥ 97% Three-phase compensation: ≤ 20.4 W/A
      Three-phase + N compensation: ≤ 22.6 W/A
      Current transformerAny ratio with 1 A or 5 A secondary; Class 1.0 accuracy; 50/60 or 400 Hz rated (instrument rated or better); Grounded; can be shared with other devices
      CT VA loading1 A: 0.04 VA 5 A: 1 VA
      Quantity of CTTwo or three CTs for three-phase loads; three CTs are required for four-wire with neutral connected loads CT position (Grid or load sense)
      Control basisClosed or open loop
      Modes or OperationMulti-modes simultaneously or discrete
      Spectrum cancellation and selection2nd to 51st harmonic order; discrete, fully selectable adjustable per harmonic order (amplitude % and ON/OFF)
      Phase harmonic correction
      Neutral harmonic correction with user-adjustable current limit up to three times unit rating
      Power factor correction (cos)
      Mains current load balancing
      Operational features% THDi setpoint, % THDv setpoint, Target PF setpoint
      Harmonic attenuation and filtering performanceTHDi < 3% in closed loop control; maximum 20:1 THDi (typical reduction with load harmonic above 50% unit rating) requires 3% or higher inductive impedance per nonlinear load
      Mains current load balancingNegative and zero sequence; selectable individually or simultaneously
      Power factor correctionOptimize PF and target PF (cos) programmable leading (capacitive) or lagging (inductive)
      Resonance avoidanceOutput at specific harmonic order turned off if resonance or lack of impedance detected or manually turned off

       

      HCU2 series

      Standard rms output current ratings380 Vac to 480 Vac: 60 A, 120 A, 200 A, 300 A

      600 Vac: 47 A, 94 A, 157 A, 235 A

      690 Vac: 40 A, 80 A, 133 A, 200 A

      Nominal frequency50/60 Hz, +/- 3 Hz auto sensing
      Number of phases3-phase
      TopologyDigital harmonic FFT

      Digital reactive power

      Lossesto 480 Vac <3%

      to 690 Vac <5%

      CT VA loading1.0 VA (5 A CT secondary)
      Spectrum cancellation2nd to 51st, discrete; fully selectable per harmonic order (amplitude and on/off)
      Control basisClosed loop (for new installations)

      Open loop compatible for retrofit applications

      Harmonic attenuationClosed loop: <3% THD(i); max 20:1 THD)i) reduction with load harmonic current above 50% of HCU2 rating

      Open loop: <5% TDD

      Required 3% or higher inductive impedance per nonlinear load

      Harmonic operational features% THDi set point

      % THDv set point

      Harmonic avoidanceOutput at specific harmonic order turned off if resonance or lack-of impedance detected; or manually turned off
      Parallal operationUp to 10 units per set of CT (to 51st order), any size combination

      Backward compatibility with Eaton HCUE operated in parallel

      Contact Eaton for applications of more than 10 units

      Parallel operation optionsMaster/master

      Master/slave

      Multi-master/multi-slave

      Same as Eaton HCUE for retrofits

      Parallel sequence optionsLead/lag with unit rotation: one unit operates to full capacity before next unit turns on; times rotation

      Load share: all operating units function at the same output percentage

      Parallel HMI controlAny unit permits viewing and changing parameter settings of complete system or any other unit in parallel system
      Parallel communicationsProprietary COM bus between operating units
      Power factor correctionOptimized unity PF, leading (capacitive) or lagging (inductive) power factor (Cos f) to target
      Control response time25 µs
      Harmonic correction time2 cycles
      Reactive correction time1/4 cycle
      Display144 mm QVGA TFT 64k-color touchscreen
      Display parametersHundreds of parameters are available. Examples include: THDi, THDv, oscilloscope for viewing many selected parameters, phasor diagrams, load power, measured currents for Ih, Is, If, I neg seq, PF (Cos f), injected currents for Ih, I reactive, I neg seq, etc.
      Communications capabilityModbus RTU, Modbus TCP/IP
      Discrete input/outputs4 input and 4 output dry contracts; assignable
      Noise level (ISO3746)<70 dB at 1 meter from unit surface
      Earthing (grounding) systemsEMC filter ground switch for Isolated Terra, high resistance ground or corner grounded systems

      Related products

      UniVAR XV

      UniVAR XV

      The UniVAR XV capacitors are metal-enclosed, medium voltage capacitors for applications with a fixed load. Providing power factor correction within a dustproof indoor or waterproof outdoor, floor mounted enclosure. 

      Read more
      Unipak filter

      Unipak filter

      The Unipak filter is a low voltage, fixed, fused power factor capacitor bank with 4.2H or 4.7H detuned reactors to protect capacitor cells in harmonically rich environments. Designed to work in heavy industrial applications with relatively constant loads, the Unipak filter features fused capacitors and reactors with cleared fuse lights and an over temperature light to make visibly accessing the health of your equipment easy. 

      Read more
      Unipak

      Unipak

      The Unipak is a low voltage, fixed, fused power factor capacitor bank for use in heavy industrial applications with a stable load where fixed capacitance can provide the most effective means of correction. With optional replaceable fusing, indicator lights for cleared fuses, and indoor/outdoor service, this small footprint capacitor can fit the specific needs of your application. 

      Read more
      LV-Transient-free static switching capacitor

      LV-Transient-free static switching capacitor

      The LV-transient-free static switched capacitor bank provides next level power system enhancements. This level of protection is ideal for high-current loads that rapidly switch on and off – such as those found in rock crushing, arc-welding, plastic injection molding and crane applications – which are typically vulnerable to power factor issues, voltage flickers, or require sag or harmonic corrections. Eaton’s Transient-free static switching device comes in two models: the FTA model and the FTE model.

      Read more
      AutoVAR 300

      AutoVAR 300

      The AutoVAR 300 is designed for low voltage applications with a variable system load where maintaining a precise target power factor is required. With a heavy-duty, three-phase capacitor construction in a small, wall-mount footprint, this product is ideal for applications with little space to spare. 

      Read more
      MV-AutoVAR

      MV-AutoVAR

      The MV-AutoVAR product line is comprised of metal-enclosed, medium voltage capacitor banks for applications with varying plant power factors. This capacitor system, which is housed within a NEMA 3R modular enclosure, automatically switches stages of capacitance in and out based on information collected by the power factor controller on the door-in-door control panel. 

      Read more
      AutoVAR filter

      AutoVAR filter

      The AutoVAR Filter is an automatically-switched, free standing power factor correction device for low voltage applications with varying loads. With built-in 4.2H and 4.7H detuned filter reactors and integrated surge protection, the AutoVAR Filter provides protection from a variety of environmental dangers.

      Read more
      AutoVAR 600

      AutoVAR 600

      The AutoVAR 600 is an automatically switched, free-standing power factor correction capacitor bank. This device is designed to meet target power factor values for low voltage applications with varying facility loads. The monitored system brings individual capacitors in and out as required to meet power factor values. 

      Read more

      DO YOU HAVE THE RIGHT PROTECTION IN PLACE?

      Equipment Failure                      Scrambled and Lost Data Facility Blackouts or Brownouts

      Paying Power                              Factor Penalties                               Frequent Downtime                    Lightning Damage

      WHO WE ARE

      About Us                                   Support                                      Seminars

      MORE INFORMATION

      White Paper                          Warranty Form                      Quotes / PQ Walk Through

      WARRANTY BTN
      • Home
      • About Us
      • Flyers
      • Products
      • Specs
      • Links
      • Blog
      • Contact us
      • Cart
      • Home
      • About Us
      • Flyers
      • Products
        • Surge Suppression Device
        • Backup Power (UPS)
        • LED Lighting
        • Infrared Cameras
        • Power Quality Recorder
        • Sonic Discharge Detector
        • Power Factor Correction Capacitors
      • Specs
      • Links
        • Power Factor Correction
        • Sag Ride Through Devices
        • Electronic Voltage Regulators
        • Powertron Generator Tap Boxes
        • NetZero LED Lighting
        • Electrical Ground Testing
      • Blog
      • Contact us
      • Cart ShoppingCart
      Manage Cookie Consent
      To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
      Functional Always active
      The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
      Preferences
      The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
      Statistics
      The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
      Marketing
      The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
      Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
      View preferences
      {title} {title} {title}

      Login

      Lost your password?

      Register

      A link to set a new password will be sent to your email address.

      Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy.

      Brought to you by WisdmLabs: WordPress Development Experts

      Sending...