Home / Reactors and Filters

AC Line/Load Reactors

Rex Power Magnetics AC Line and Load Reactors are designed to improve power quality, protect equipment, and extend the life of electrical systems.

Send an email to: nacho@apowersystems.com, or call to +1 813-805-9506
Product categories
  • Backup Power (UPS)
    • Data Center & Facility UPS
    • Eaton 3S UPS
    • Eaton 5P RM UPS
    • Eaton 5P Tower UPS
    • Eaton 5PX UPS
    • Eaton 5S UPS
    • Eaton 5SC Tower UPS
    • Eaton 9130 Rackmount UPS
    • Eaton 9130 UPS
    • Eaton 9155 UPS
    • Eaton 9170+ UPS
    • Eaton 9355 UPS
    • Eaton 93E UPS
    • Eaton 93PM UPS
    • Eaton 9PX Split Phase 6kVA & 10kVA UPS
    • Eaton 9PX UPS
    • Eaton BladeUPS
    • Eaton Ferrups UPS
    • Network, Server & Storage UPS
  • Docking Stations
  • Infrared Cameras
  • LED Lighting
  • Low Voltage Distribution Transformers
  • Power Conditioning
  • Power Distribution Center
  • Power Factor Correction Capacitors
  • Power Quality Recorder
  • Power Storage
  • Reactors and Filters
  • Rectifiers
  • Sonic Discharge Detector
  • Surge Protective Devices
    • Bussmann by Eaton
    • Eaton PSPD Series
    • Innovative Technology
      • Critical Load
      • Equalizer
      • Marine Grade SPD
      • OEM
      • Protector
      • Residential
      • XT Series
  • Transfer Switches
  • Description

Rex Power Magnetics AC Line and Load Reactors are designed to improve power quality, protect equipment, and extend the life of electrical systems. Installed on the line or load side of variable frequency drives (VFDs), motor controllers, and other sensitive equipment, these reactors limit harmonic distortion, reduce voltage spikes, and mitigate current surges.

Each reactor is engineered for precise inductance, low losses, and superior thermal performance. Constructed using high-grade core steel, copper or aluminum windings, and robust insulation systems, Rex reactors provide reliable operation under continuous and transient conditions. Their dry-type construction and durable enclosures make them suitable for harsh industrial environments.

Available in a wide range of current ratings and voltage classes, Rex AC Line and Load Reactors can be tailored to specific system requirements. All units are designed and tested to meet applicable CSA and UL standards, ensuring safe, efficient, and long-lasting performance in demanding applications.

 

Capacity  2A to 1,250 A Three Phase
Voltage Class  600V Max
Cooling  Air Cooled (ANN / AN)
Frequency  60Hz (50/60Hz Optional)
Conductors  Copper (Cu) Windings
Insulation System  220°C Insulation System (150 °C Temp Rise Max)
Sound Level  Below 40dBA
Overload Capability  150% of rated current for 1 min.
Saturation Level  Not less than 250% of rated current (min 50% of rated inductance at 350% rated current)
Enclosure Type   Type 1 Indoor
Warranty  12 Months
Quality System  ISO 9001:2015 Quality Management System
Certifications
  • CSA Certified
  • UL Listed
Reference Standards
  • IEEE C57.110
  • NEMA ST-20

Related products

Motor Guarding Transient Filters

Motor Guarding Transient Filters

Rex Power Magnetics Motor Guarding Transient Filters are engineered to protect motors and cables from voltage spikes, steep dv/dt waveforms, and reflected wave phenomena generated by variable frequency drives (VFDs)

Read more

DO YOU HAVE THE RIGHT PROTECTION IN PLACE?

Equipment Failure                      Scrambled and Lost Data Facility Blackouts or Brownouts

Paying Power                              Factor Penalties                               Frequent Downtime                    Lightning Damage

WHO WE ARE

About Us                                   Support                                      Seminars

MORE INFORMATION

White Paper                          Warranty Form                      Quotes / PQ Walk Through

WARRANTY BTN
  • Home
  • About Us
  • Flyers
  • Products
  • Specs
  • Links
  • Blog
  • Contact us
  • Cart
  • Home
  • About Us
  • Flyers
  • Products
    • Surge Suppression Device
    • Backup Power (UPS)
    • Reactors and Filters
    • Low Voltage Distribution Transformers
    • Equipment Rental
    • Power Factor Correction Capacitors
    • Power Quality Recorder
    • Infrared Cameras
    • LED Lighting
    • Sonic Discharge Detector
  • Specs
  • Links
    • Power Factor Correction
    • Sag Ride Through Devices
    • Electronic Voltage Regulators
    • Powertron Generator Tap Boxes
    • NetZero LED Lighting
    • Electrical Ground Testing
  • Blog
  • Contact us
  • Cart ShoppingCart
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}

Login

Lost your password?

Brought to you by WisdmLabs: WordPress Development Experts

Sending...